224 research outputs found

    Open-source software in medical imaging: development of OsiriX

    Get PDF
    Purpose Open source software (oss) development for medical imaging enables collaboration of individuals and groups to produce high-quality tools that meet user needs. This process is reviewed and illustrated with OsiriX, a fast DICOM viewer program for the Apple Macintosh. Materials and methods OsiriX is an oss for the Apple Macintosh under Mac OS X v10.4 or higher specifically designed for navigation and visualization of multimodality and multidimensional images: 2D Viewer, 3D Viewer, 4D Viewer (3D series with temporal dimension, for example: Cardiac-CT) and 5D Viewer (3D series with temporal and functional dimensions, for example: Cardiac-PET-CT). The 3D Viewer offers all modern rendering modes: multiplanar reconstruction, surface rendering, volume rendering and maximum Intensity projection. All these modes support 4D data and are able to produce image fusion between two different series (for example: PET-CT). OsiriX was developed using the Apple Xcode development environment and Cocoa framework as both a DICOM PACS workstation for medical imaging and an image processing software package for medical research (radiology and nuclear imaging), functional imaging, 3D imaging, confocal microscopy and molecular imaging. Results OsiriX is an open source program by Antoine Rosset, a radiologist and software developer, was designed specifically for the needs of advanced imaging modalities. The software program turns an Apple Macintosh into a DICOM PACS workstation for medical imaging and image processing. OsiriX is distributed free of charge under the GNU General Public License and its source code is available to anyone. This system illustrates how open software development for medical imaging tools can be successfully designed, implemented and disseminated. Conclusion oss development can provide useful cost effective tools tailored to specific needs and clinical tasks. The integrity and quality assurance of open software developed by a community of users does not follow the traditional conformance and certification required for commercial medical software programs. However, open software can lead to innovative solutions designed by users better suited for specific task

    General Consumer Communication Tools for Improved Image Management and Communication in Medicine

    Get PDF
    We elected to explore new technologies emerging on the general consumer market that can improve and facilitate image and data communication in medical and clinical environment. These new technologies developed for communication and storage of data can improve the user convenience and facilitate the communication and transport of images and related data beyond the usual limits and restrictions of a traditional picture archiving and communication systems (PACS) network. We specifically tested and implemented three new technologies provided on Apple computer platforms. (1) We adopted the iPod, a MP3 portable player with a hard disk storage, to easily and quickly move large number of DICOM images. (2) We adopted iChat, a videoconference and instant-messaging software, to transmit DICOM images in real time to a distant computer for conferencing teleradiology. (3) Finally, we developed a direct secure interface to use the iDisk service, a file-sharing service based on the WebDAV technology, to send and share DICOM files between distant computers. These three technologies were integrated in a new open-source image navigation and display software called OsiriX allowing for manipulation and communication of multimodality and multidimensional DICOM image data sets. This software is freely available as an open-source project at http://homepage.mac.com/rossetantoine/OsiriX. Our experience showed that the implementation of these technologies allowed us to significantly enhance the existing PACS with valuable new features without any additional investment or the need for complex extensions of our infrastructure. The added features such as teleradiology, secure and convenient image and data communication, and the use of external data storage services open the gate to a much broader extension of our imaging infrastructure to the outside worl

    Assessment of various strategies for 18F-FET PET-guided delineation of target volumes in high-grade glioma patients

    Get PDF
    Purpose: The purpose of the study is to assess the contribution of 18F-fluoro-ethyl-tyrosine (18F-FET) positron emission tomography (PET) in the delineation of gross tumor volume (GTV) in patients with high-grade gliomas compared with magnetic resonance imaging (MRI) alone. Materials and methods: The study population consisted of 18 patients with high-grade gliomas. Seven image segmentation techniques were used to delineate 18F-FET PET GTVs, and the results were compared to the manual MRI-derived GTV (GTVMRI). PET image segmentation techniques included manual delineation of contours (GTVman), a 2.5 standardized uptake value (SUV) cutoff (GTV2.5), a fixed threshold of 40% and 50% of the maximum signal intensity (GTV40% and GTV50%), signal-to-background ratio (SBR)-based adaptive thresholding (GTVSBR), gradient find (GTVGF), and region growing (GTVRG). Overlap analysis was also conducted to assess geographic mismatch between the GTVs delineated using the different techniques. Results: Contours defined using GTV2.5 failed to provide successful delineation technically in three patients (18% of cases) as SUVmax < 2.5 and clinically in 14 patients (78% of cases). Overall, the majority of GTVs defined on PET-based techniques were usually smaller than GTVMRI (67% of cases). Yet, PET detected frequently tumors that are not visible on MRI and added substantially tumor extension outside the GTVMRI in six patients (33% of cases). Conclusions: The selection of the most appropriate 18F-FET PET-based segmentation algorithm is crucial, since it impacts both the volume and shape of the resulting GTV. The 2.5 SUV isocontour and GF segmentation techniques performed poorly and should not be used for GTV delineation. With adequate setting, the SBR-based PET technique may add considerably to conventional MRI-guided GTV delineatio

    Functional imaging of head and neck squamous cell carcinoma with diffusion-weighted MRI and FDG PET/CT: quantitative analysis of ADC and SUV

    Get PDF
    Purpose: Head and neck squamous cell carcinoma (HNSCC) may cause a decreased apparent diffusion coefficient (ADC) on diffusion-weighted magnetic resonance imaging (DW MRI) and an increased standardized uptake value (SUV) on fluorodeoxyglucose (FDG) positron emission tomography (PET/CT). We analysed the reproducibility of ADC and SUV measurements in HNSCC and evaluated whether these biomarkers are correlated or independent. Methods: This retrospective analysis of DW MRI and FDG PET/CT data series included 34 HNSCC in 33 consecutive patients. Two experienced readers measured tumour ADC and SUV values independently. Statistical comparison and correlation with histopathology was done. Intra- and inter-observer agreement for ADC and SUV measurements was assessed. Results: Intraclass correlation coefficient (ICC) analysis showed almost perfect reproducibility (>0.90) for ADCmean, ADCmin, SUVmax and SUVmean values for intra-observer and inter-observer agreement. Mean ADCmean and ADCmin in HNSCC were 1.05 ± 0.34 × 10−3 mm2/s and 0.65 ± 0.29 × 10−3 mm2/s, respectively. Mean SUVmean and mean SUVmax were 7.61 ± 3.87 and 12.8 ± 5.0, respectively. Although statistically not significant, a trend towards higher SUV and lower ADC was observed with increasing tumour dedifferentiation. Pearson's correlation analysis showed no significant correlation between ADC and SUV measurements (r −0.103, −0.051; p 0.552, 0.777). Conclusion: Our data suggest that ADC and SUV values are reproducible and independent biomarkers in HNSC

    Approaches for the optimization of MR protocols in clinical hybrid PET/MRI studies

    Get PDF
    Magnetic resonance imaging (MRI) is the examination method of choice for the diagnosis of a variety of diseases. MRI allows us to obtain not only anatomical information but also identification of physiological and functional parameters such as networks in the brain and tumor cellularity, which plays an increasing role in oncologic imaging, as well as blood flow and tissue perfusion. However, in many cases such as in epilepsy, degenerative neurological diseases and oncological processes, additional metabolic and molecular information obtained by PET can provide essential complementary information for better diagnosis. The combined information obtained from MRI and PET acquired in a single imaging session allows a more accurate localization of pathological findings and better assessment of the underlying physiopathology, thus providing a more powerful diagnostic tool. Two hundred and twenty-one patients were scanned from April 2011 to January 2012 on a Philips Ingenuity TF PET/MRI system. The purpose of this review article is to provide an overview of the techniques used for the optimization of different protocols performed in our hospital by specialists in the following fields: neuroradiology, head and neck, breast, and prostate imaging. This paper also discusses the different problems encountered, such as the length of studies, motion artifacts, and accuracy of image fusion including physical and technical aspects, and the proposed solution

    [11C]acetate PET/CT Visualizes Skeletal Muscle Exercise Participation, Impaired Function, and Recovery after Hip Arthroplasty; First Results

    Get PDF
    Purpose: Based on skeletal muscle acetate physiology we aimed studying muscle function after hip arthroplasty with [11C]acetate PET. Procedures: Two male patients were investigated 3 and 12weeks after hip arthroplasty with muscle [11C]acetate PET/CT performed at rest and exercise. Median muscle SUVmean were calculated on three non-consecutive transverse PET slices. Results: The four exercise PET/CT showed, compared with rest, consistent increase in [11C]acetate uptake in active muscles contralateral to surgery. On the arthroplasty side most muscles showed symmetric activity increase under exercise both at 3 and 12weeks after surgery, but four muscles showed only minor activity increase at 3weeks. At 3months, functional recovery of the latter four muscles was observed. Conclusion: Consistent increase in [11C]acetate uptake in healthy muscles under exercise compared with rest was observed by PET/CT. Transiently impaired muscle function 3weeks after surgery recovered at 3months. These first observations merit further investigatio
    • …
    corecore